The K3A 3-axis sensor is designed for measuring force in three mutually perpendicular axes.
This product group has a wide measurement ranges for the forces.
The K3A S3-Axis Force Sensors are developed for the following applications:
A key characteristic of 3D force sensors is crosstalk: applying a force also triggers a measurement in the two unloaded axes. Thanks to several compensation mechanisms (mechanical and electrical), crosstalk is typically less than 3% of the nominal load. Crosstalk is reproducible and proportional to the amplitude of the applied force. By applying an additional compensation matrix, crosstalk in all axes can be reduced to a maximum of less than 1%.
By default, you receive two factory calibrations, each with two measurement points:
one without a compensation matrix (“cv”) and one with extended matrix compensation (“s”).
For detailed proof of the sensor's linearity, you can optionally extend the calibration to 4 or 6 measurement points:
This ensures your sensor is optimally calibrated to your application from the very first measurement.
required accessories: connector 12p/f/M12/5,0/ME
recommended accessories: measuring amplifier GSV-5A3 SubD44HD, GSV-8DS SubD44HD, Configuration SubD44HD/m/3ch, Configuration SubD44HD/m/3ch/TEDS (for GSV-8DS)
The K3A 3-axis sensor is designed for measuring force in three mutually perpendicular axes.
This product group has a wide measurement ranges for the forces.
The K3A S3-Axis Force Sensors are developed for the following applications:
A key characteristic of 3D force sensors is crosstalk: applying a force also triggers a measurement in the two unloaded axes. Thanks to several compensation mechanisms (mechanical and electrical), crosstalk is typically less than 3% of the nominal load. Crosstalk is reproducible and proportional to the amplitude of the applied force. By applying an additional compensation matrix, crosstalk in all axes can be reduced to a maximum of less than 1%.
By default, you receive two factory calibrations, each with two measurement points:
one without a compensation matrix (“cv”) and one with extended matrix compensation (“s”).
For detailed proof of the sensor's linearity, you can optionally extend the calibration to 4 or 6 measurement points:
This ensures your sensor is optimally calibrated to your application from the very first measurement.